Description: RADF original reading start sensor abnormality: The automatic adjustment for the original reading start sensor has been performed, but is ended unsuccessfully.
Remedy: 1. Check if the RADF original reading start sensor is not damaged or stained. 2. Check that the prism is installed in the correct position and that it is not damaged. 3. Check if the connector CN75 on the RADF board is disconnected from the RADF original reading start sensor or the harnesses are open circuited. Correct if so. 4. Replace the RADF original reading start sensor, and then perform the automatic adjustment for the original reading start sensor (05-356). 5. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356).