Mã lỗi CE20 — Toshiba e-Studio 5530c

Code: CE20

Description: Image quality sensor abnormality (no pattern level): The output value of this sensor is out of a specified range when the image quality control test pattern is not formed.
Remedy: Are there any abnormal stains (cleaning defects), large scratches or breaking on the transfer belt surface? Are the drum and the transfer belt rotating? NO <Checking procedure> 1. Check if the transfer belt unit is securely installed. Correct it if not. 2. Check if any toner image remains on the transfer belt surface. If any, check the installation status of the TBU cleaner unit. If there is any abnormality, correct it, and clean the transfer belt. 3. Check if the drum and the transfer belt are properly operated. (ON: 03-101 / OFF: 03-151) If they are not rotating normally, check if their drive gears are damaged or if they contact the equipment. Correct it if needed. Proceed to step (6). (to step (1) for the second time) YES Is the sensor shutter of the image quality sensor opening or closing normally? Or is it damaged? Is the sensor surface of the image quality sensor stained with toner? If so, has it been cleaned? NO <Checking procedure> 1. Take off the transfer belt unit so that you can see the sensor unit. 2. Check if the sensor shutter is opening or closing normally. (Opening: 03-118 / Closing: 03-168) If the sensor shutter is not opening or closing, check if it is damaged or there is any abnormality in the sensor shutter solenoid. Check the connector and the harness between the sensor shutter solenoid and the LGC board. (LGC CN307-A7pin, A8pin) 3. Slide the sensor shutter so that the sensor surface can be seen. 4. Clean the sensor surface with a cotton swab or a soft cloth. 5. Clean the area around the sensor (e.g.: sensor shutter) if it is stained, so that the sensor surface does not become dirty. Proceed to step (6). (to step (1) for the second time) YES Is the connector of the image quality sensor securely connected? Is the connector CN307 on the LGC board securely connected? Is the harness between the LGC board and the image quality sensor disconnected? NO <Checking procedure> • Reconnect the connector. • Replace the harness. Proceed to step (6). (to step (1) for the second time) YES Is +12V power supply voltage normally supplied to the image quality sensor? Is +12V voltage normally output by the CN301-9pin on the LGC board? NO <Checking procedure> 1. Check if +12V voltage is output by the switching power supply (PS-ACC CN404-7pin). 2. Check if +12V voltage is output by the CN301-9pin on the LGC board. Check if the supply harness between the switching power supply and the LGC board is open circuited, damaged or disconnected. Proceed to step (6). (to step (1) for the second time) YES (1) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Drum surface potential sensor control setting (08-2561)” to “0” (Invalid). (2) Perform “Enforced performing of image quality open-loop control (05-394)”. (3) Output the image quality control test pattern (04-270) more than one time and the list print ([9][START]) in the adjustment mode (05), and then check if the image is normal. Normal Abnormal Abnormal image: Blank print, Solid print, White banding, Color banding, White spots, Poor transfer, Uneven image density, Faded image (low density), Uneven light distribution, Blotched image. * Blank print: including when one of the YMCK colors is not printed. Correct the abnormal image. Proceed to step (5). (4) Replace the image quality sensor or the LGC board. (5) Set the values of “Image quality closed-loop control / Contrast voltage (08-556)” and “Drum surface potential sensor control setting (08-2561)” to “1” (Valid). (6) Perform “Automatic initialization of image quality control (05-396)” and make sure it is completed normally. (Error [CE10], [CE20] and [CE40] do not appear.) Then perform “Automatic gamma adjustment”. | When an error occurs: Check and correct it accordingly. (7) Reset all of the values in the codes “Abnormality detection count (Y/M/C/K) Display/0 clearing (08-573 to 08-576)”.

← Xem tất cả mã lỗi Toshiba e-Studio 5530c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie