Mã lỗi E400 — Toshiba e-Studio 5530c

Code: E400

Description: Duplexing unit open jam
Remedy: 1. Close the duplexing unit if it is opened. Remove if there is any paper before closing it. 2. Is the voltage of 24V being supplied from the power supply unit? (Perform the input check: 03- [COPY] ON/[6]/[A]) 3. Check if the connector CN309 on the LGC board is disconnected from the connector CN403 on the switching regulator or the harnesses are open circuited. Correct if any. 4. Check if the fuse (F201, F202, F203, and F204) on the switching regulator has blown. 5. Replace the PFC board. 6. Replace the switching regulator. 7. Is the interlock switch working properly? (Perform the input check: 03-[SCAN] ON/[4]/[G]) 8. Check if the connector CN312 on the LGC board is disconnected from the interlock switch or the harnesses are open circuited. Correct if any.

← Xem tất cả mã lỗi Toshiba e-Studio 5530c