Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E980 — Toshiba e-Studio 5530c

Code: E980

Description: Stop jam at the lower paper exit sensor: Paper transported from the bridge unit does not pass the lower paper exit sensor.
Remedy: 1. Is the lower paper exit sensor working? (Perform the input check: 03-[COPY]ON/[5]/[G]). * If it is working properly, proceed to 6. If not, check 2 to 5 below. 2. Check if the connector CN516 on the PFC board is disconnected from the exit sensor or the harnesses are open circuited. Correct if so. 3. Check if the lower paper exit sensor is correctly installed or the actuator is properly moved. 4. Replace the upper paper exit sensor. 5. Replace the PFC board. 6. Is the exit motor working? (Perform the output check: 03-140) * If it is working properly, proceed to 10. If not, check 7 to 9 below. 7. Check if the connector CN515 on the PFC board is disconnected from the bridge unit transport exit motor or the harnesses are open circuited. Correct if so (including CN537, 539, 540 on the DRV board). 8. Replace the exit motor. 9. Replace the PFC board. 10.Check if there is any abnormality on the driving section of the exit motor or the roller. Correct if any.