Mã lỗi CE41 — Toshiba e-Studio 5540c

Code: CE41

Description: Image quality TRC control test pattern abnormality: The image quality TRC control test pattern is not printed normally.
Causes: HDD SYS board
Remedy: 1 Check each value of the subcodes 2 (Y), 5 (M), 8 (C) and 11 (K) of the code 05- 2803. Under 628 (Y, M, C and K) (High density pattern abnormality) <Procedure> 1. Set both values of the codes 08-2600 and 08-8103 to 0. 2. Print the test chart 04-270 with A3/LD for more than 2 pages. Then perform list printing ([9]+[START]) to check if no abnormality is found in the image density. If any abnormality is found, correct it referring to “25.5 Troubleshooting for the Image” 3. .Check if the process unit (EPU tray) and the developer unit are installed properly. 4. Check if any toner or developer material is spilt around the laser shutter. Clean if so. 5. Check the center position adjustment for each drawer is within the range preset at the shipment (rear side: 0-3 mm). "[B] Adjustment of the gear holder" 6. Adjust the image dimension with A3/LD. "[A] Reproduction ratio of primary scanning direction (Image clock fine adjustment (Printer))" "[B] Primary scanning data laser writing start position (Laser writing start position (Printer))" 7. Return both values of the codes 08-2600 and 08-8103 to 1. Then proceed to step 3. If it is the second time, proceed to step 4. 2 628 or above (Y, M, C and K) 2 2.Check each value of the subcodes 0 (Y), 3 (M), 6 (C) and 9 (K) of the code 05- 2800. 180 or above (Y, M, C, K all) 3 Under 180 (Y, M, C, K each) (Low density pattern abnormality) <Procedure> 1. Set both values of the codes 08-2600 and 08-8103 to 0. 2. Print the test chart 04-270 with A3/LD for more than 2 pages. Then perform list printing ([9]+[START]) to check that no abnormality is found in the image density. If any abnormality is found, correct it referring to “"8.5 Troubleshooting for the Image" 3. Return both values of the codes 08-2600 and 08-8103 to 1. Then proceed to step 3. If it is the second time, proceed to step 4. 3 Perform the automatic gamma adjustment. If the adjustment is normally finished, this is the end of the procedure. If the error CE41 still occurs, repeat the procedure from step 1. 4 4.Check if the harness between the connector CN423 on the IMG board and the connector CN319 on the LGC board is disconnected or open circuited. Correct if so. 5 5.Check if the harness between the connector CN424 on the IMG board and the connector CN320 on the LGC board is disconnected or open circuited. Correct if so. 6 6.Check if the conductor patterns on the IMG board and the LGC board are short circuited or open circuited. 7 7.If no abnormality is found in steps 4 to 6 above, replace the IMG board. 8 8.Perform automatic gamma adjustment. If the adjustment is normally finished, this is the end of the procedure. If the error CE41 still occurs, proceed to step 9. 9 9.Reinstall the removed IMG board and then replace the LGC board. Perform automatic gamma adjustment after the board is replaced.

← Xem tất cả mã lỗi Toshiba e-Studio 5540c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie