Mã lỗi CEC0 — Toshiba e-Studio 5540c

Code: CEC0

Description: 2nd transfer roller position detection abnormality: The 2nd transfer roller does not contact/release normally.
Causes: 2nd transfer roller position detection sensor 2nd transfer cam motor LGC board
Remedy: 2nd transfer cam motor (M48) • 2nd transfer cam motor check (Perform the output check: 243) • Connector check • Harness check 2nd transfer roller position detection sensor (S50) • Sensor check (Perform the input check: 03-[ALL]OFF/[9]/[H]) • Connector check • Harness check LGC board • Connector check (CN307, CN314) • Board check 2nd transfer contact/release cam unit gear • Check that it is not damaged. Actuator in the TRU • Check that it is installed properly. • Check that it is not damaged. Sensors in the TRU • Check that they are installed properly. • Check that the cam is not damaged.