Mã lỗi E731 — Toshiba e-Studio 555

Code: E731

Description: Stop jam at the original exit sensor: The trailing edge of the original does not pass the original exit sensor after its leading edge has reached this sensor
Remedy: 1. Clean the exit roller and the exit intermediate roller if they are stained. 2. Is the original exit sensor working? (Perform the input check: 03-[FAX]ON/[7]/[E]) * If it is working properly, proceed to 6. If not, check 3 to 5 below. 3. Check if the connector CN75 on the RADF board is disconnected from the original exit sensor or the harnesses are open circuited. Correct if any. 4. Replace the original exit sensor. 5. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356). 6. Replace the exit roller and the exit intermediate roller if they are worn out.