Description: Original jam access cover open: The Original jam access cover has opened during RADF operation.
Remedy: 1. Close the original jam access cover or the original reverse unit if they are opened. Remove if there are any original before closing them. 2. Is the original jam access cover opening/closing sensor and the original revese unit opening/ closing sensor working? (Perform the input check: 03) Original jam access cover opening/closing sensor: 03-[FAX]ON/[7]/[C], Original revese unit opening/closing sensor: 03-[FAX]ON/[5]/[C] * If it is working properly, proceed to 6. If not, check 3 to 5 below. 3. Check if the connector CN74 or CN75 on the RADF board is disconnected from the original jam access cover opening/closing sensor, original revese unit opening/closing sensor or the harnesses are open circuited. Correct if any. 4. Replace the original jam access cover opening/closing sensor or the original revese unit opening/closing sensor. 5. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356).