Description: Peak detection error: Lighting of the exposure lamp (white reference) is not detected when the power is turned ON.
Remedy: Does the exposure lamp light? (Perform the output check in the test mode: 03-267) ↓ → YES → 1. Check if the connectors on the CCD and SLG boards are disconnected. 2. Check if the shading correction plate is detached or dirty. 3. Check if the conductor pattern on the CCD board is short circuited or open circuited. 4. Check if the conductor pattern on the SLG board is short circuited or open circuited. 5. Replace the lens unit. 6. Replace the SLG board. NO 1. Check if the connectors of the exposure lamp and inverter are disconnected. 2. Check the SLG board if the connector pin CN1 is disconnected and the harness is short circuited or open circuited. 3. Check if the conductor pattern on the SLG board is short circuited or open circuited. 4. Replace the SLG board. 5. Replace the inverter. 6. Replace the exposure lamp.