Mã lỗi E001-0000 — Canon i-SENSYS MF4450

Code: E001-0000

Description: Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature 235 deg C) during temperature control
Remedy: - When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies.
(1) Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the Main Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal.
[1] 100 V machine - Heater resistance: 12.9 U ±7%
[2] 120 V machine - Heater resistance: 16.0 U ±7%
[3] 230 V machines - Heater resistance: 53.8 U ±7%
(2) Check the connection of connector (J101) on the Engine Controller Board.
(3) Check the connection of connector (J552) on Engine Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the Engine Controller Board.