Mã lỗi C467 — Toshiba e-Studio 5560C

Code: C467

Description: Pressure roller thermistor abnormality after entering ready status (temperature abnormality at ready status)
Causes: Pressure roller thermistor Fuser unit Power supply LGC board
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) • Connector check (CN403, CN409) Pressure roller thermistor • Sensor check • Install check • Is the pressure roller rear thermistor contacted with the pressure roller surface securely? Fuser unit • Unit check • Connector check • Harness check LGC board • Connector check (CN301, CN306) • Harness check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value (08-2002) “5”, “6”, “8”, “18”, “20”, “26”, “28”, “33” or “34” to “0” 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. Remarks: The status counter value is set as follows in the following cases. • The error occurred during warming-up: “5” or “6” • The error occurred after the equipment has become ready: “33” • Regardless of the equipment's status (i.e. during warming-up or in ready status), when the temperature detected by the pressure roller thermistor is 210„aC or higher: “8”, “18”, “20”, “26” or “28”. The error occurred during printing: “34”