Code: E910
Description: Jam at the bridge unit transport sensor 1: The paper does not reach the bridge unit transport sensor 1 after it has passed the exit sensor.
Causes: Bridge unit transport sensor-1 Bridge unit transport entrance motor Bridge unit transport exit motor LGC board DRV board PFC board Roller Transport roller of the bridge unit
Remedy: Bridge unit • Check if there is any paper in the bridge unit and remove it if there is Bridge unit path entrance sensor • Sensor check (Perform the input check: 03-[ALL]OFF/[1]/[B], 03- [SCAN]ON/[3]/[D]) • Connector check • Harness check Transport path switching solenoid-1 • Solenoid check (Perform the output check: 03-275) • Connector check • Harness check Bridge unit transport entrance motor Bridge unit transport exit motor • Motor check (Perform the output check (Bridge unit transport entrance motor): 03-130/180) (Perform the output check (Bridge unit transport exit motor): 03-136) • Connector check • Harness check LGC board • Connector check (CN307) • Board check DRV board • Connector check (CN537, CN539) • Harness check • Board check PFC board • Connector check (CN500, CN515) • Harness check • Board check