Description: IH control circuit abnormality or IH coil abnormality: The IH control circuit is under abnormal conditions, or the IH coil is broken or has a short-circuit.
Remedy: 1. Check the power voltage Is the voltage normal? (Is the voltage during the operation ±10% of the rated voltage?) 2. Check the IH control board (1) Check if the harness of IH coil is loosened. (2) Check if the conductor pattern on the board is short circuited or open circuited. (3) Replace the IH control board. 3. Check the IH coil (1) Check if the coil is broken or shorted. (2) Replace the IH coil. 4. Clear the status counter Change the current status counter value (08-400) "17" to "0". [C47X], [C481] and [C490] can be cleared by turning OFF and ON the main switch as long as the problem was solved, and the status counter does not have to be changed to "0". The value of the status counter remains until the next service call overwrites the value.