Mã lỗi E450 — Toshiba e-Studio 556SE

Code: E450

Description: Option LCF side cover open jam: The side cover of the Option LCF has opened during printing.
Remedy: Is the LCF front cover open? → YES → Remove the paper if there is any, then close the cover. NO Is the LCF side cover opening/closing switch working? (Perform the input check in the test mode: 03-[FAX]OFF/[5]/[B]) ↓ → NO → 1. Check if the connector of the LCF side cover opening/closing switch is disconnected. 2. Check if either of the connectors CN100 or CN106 on the LCF board is disconnected. 3. Check if the connector CN338 on the LGC board is disconnected. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 6. Replace the LCF side cover opening/closing switch. 7. Replace the LCF board. 8. Replace the LGC board. YES 1. Replace the LCF board. 2. Replace the LGC board.