Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C180 — Toshiba e-Studio 557

Code: C180

Description: Tandem LCF tray-up motor abnormality: The Tandem LCF tray-up motor does not run normally or the Tandem LCF tray does not move normally. (Feeding of any other drawer than the Tandem LCF is possible.)
Remedy: Does the tray move? (Perform the output check in the test mode: 03-270) ↓ → NO → 1. Check if the connector of the Tandem LCF tray-up motor is disconnected. 2. Check if the connector CN345 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 5. Replace the LCF tray-up moter. 6. Replace the LGC board. YES Are the 3rd drawer/tandem LCF tray-up sensor and tandem LCF bottom sensor working? (Perform the input check in the test mode: 03-[FAX]OFF/[3]/[E], /[8]/[F]) ↓ → NO → 1. Check if the connectors of the sensors are disconnected. 2. Check if the connector CN328, CN345 on the LGC board is disconnected. 3. Check if the slit reaches the sensors. 4. Check if the connector pins are disconnected and the harnesses are open circuited. 5. Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 6. Replace the LGC board. YES 1. Check if the driving mechanism is abnormal. 2. Check if the conductor pattern on the LGC board is short circuited or open circuited. 3. Replace the LGC board.

← Xem tất cả mã lỗi Toshiba e-Studio 557

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie