Mã lỗi E712 — Toshiba e-Studio 557

Code: E712

Description: Jam not reaching the original registration sensor: The original fed from the original feeding tray does not reach the original registration sensor.
Remedy: 1. Clean the pickup roller, feed roller and separation roller if they are stained. 2. Flatten the original if it is folded or excessively curled and place it again. 3. Is the original registration sensor working? (Perform the input check: 03-[FAX]ON/[7]/[H]) * If it is working properly, proceed to 7. If not, check 3 to 6. 4. Check if the connector CN74 on the RADF board is disconnected from the original registration sensor or the harnesses are open circuited. Correct if any. 5. Replace the original registration sensor. 6. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356). 7. Replace the pickup roller, feed roller and separation roller if they are worn out.