Description: Transport/exit signal reception jam: The RADF has received the transport/exit signal from the equipment while no original is at the exposure waiting position.
Remedy: 1) If the original remains in the RADF, remove it. 2) If any paper remains in the equipment, remove it. 3) Turn the power OFF and then back ON. If the jam still occurs, lead the following procedure. 4) Check the connection between the ADF board and SLG board, and the connection between the ADF board and switching power supply. - Are the connection of the connectors and joint connectors normal? - Are the connector pins disconnected or are the harnesses open circuited? 5) Check if the 24V and 5V outputs of the switching power supply are normal. 6) Check if the conductor pattern on the ADF board is short circuited or open circuited. 7) Replace the ADF board. 8) Check if the conductor pattern on the SLG board is short circuited or open circuited. 9) Replace the SLG board.