Code: CB70
Description: Stack amount detection sensor abnormality
Remedy: [Procedure 1] Is the problem solved by turning OFF and ON the power of the equipment? → YES. END NO Is the wiring between the finisher controller PC board and the height sensor (PS1) correct? → YES. Correct the wiring. NO Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC? → NO. Replace the finisher controller PC board. YES Re-adjust the height sensor. Replace the height sensor if it still causes the problem. [Procedure 2] Is the connector J6 on the finisher controller PC board, J114 of the height sensor (PS1) or relay connector J212 and J213 disconnected? → YES. Connect the connector(s). NO Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC? → NO. Replace the finisher controller PC board. YES Is the wiring between the finisher controller PC board and height sensor correct? → YES. Correct the wiring. NO Replace the height sensor. [Procedure 3] Is the problem solved by readjusting the DIP switch? → YES. END NO Is the wiring between the finisher controller PC board and height sensor (PS1) correct? → YES. Correct the wiring. NO Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC? → NO. Replace the finisher controller PC board. YES Replace the height sensor.