Code: C445
Description: Heater lamp abnormality after abnormality judgment (pre-running end temperature abnormality)
Remedy: 1,2,3,4. Check the thermopiles, Heater and LGC board Check the above components following the procedures 1, 2,3 and 4 for [C411/C412]. 5. Clear the status counter Change the current status counter value (08-400) “3”, “5”, “6”, “9”, “19”, “21”, “22”, “23”, “24”, “25”, “27” or “29” to “0” for [C44X], taking the same procedure as that for [C41X]. • The status counter value is as follows in the following cases. - The error occurred during warming-up: “3”, “5” or “6” - The error occurred after the equipment has become ready: “7” - The temperature detected by the fuser belt center thermopile is 230°C or higher, the temperature detected by the side thermopile is 230°C or higher or the temperature detected by the edge thermopile is 230°C or higher: “9”, “19”, “21”, “22”, “23”, “25”, “27” or “29”. - The error occurred during printing: “24” or “25 - The error occurred during energy saving: “27” - A paper jam occurred: “29”