Remedy: (1) Check if the connector CN304 on the LGC board is completely inserted or not disconnected. (2) Check if the connectors CN423 and CN424 on the IMG board and the connectors CN319 and CN320 on the LGC board are completely inserted. (3) Check if the connector pin between the IMG board (connector CN423, CN424) and the LGC board (connector CN319, CN320) is disconnected. (4) Check if the connector CN426 on the IMG board is completely inserted or not disconnected. (5) Check if the conductor patterns on the IMG board and the LGC board are short circuited or open circuited. (6) Replace the LGC board if no problem is found in steps from (1) to (5) above. (7) If the problem is not corrected with the replacement of the LGC board, reinstall the removed LGC board and replace the IMG board. (8) If the problem is still not corrected with the replacement of the IMG board, reinstall it and ask a specialist to repair it. (Abnormal ID)