Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E580 — Toshiba e-Studio 6530c

Code: E580

Description: Stop jam at the bridge unit
Remedy: 1. Is the reverse sensor working? (Perform the input check: 03-[SCAN]ON/[3]/[E].)) * If it is working properly, proceed to 6. If not, check 2 to 5 below. 2. Check if the connector CN514 on the PFC board is disconnected from the reverse sensor or the harnesses are open circuited. Correct if so (including CN538 and CN539 on the DRV board). 3. Check if the reverse sensor is correctly installed or its detecting element is not damaged or stained. 4. Replace the reverse sensor. 5. Replace the PFC board. 6. Are the bridge unit transport exit motor and the reverse motor working? (Perform the output check: 03-132-134, 03-136.) * If they are working properly, proceed to 11. If not, check 7 to 10 below. 7. Check if the connector CN515 on the PFC board is disconnected from the bridge unit transport exit motor or the reverse motor, or the harnesses are open circuited. Correct if so (including CN537 and CN539 on the DRV board). 8. Replace the bridge unit transport exit motor or the reverse motor. 9. Replace the DRV board. 10.Replace the PFC board. 11.Check if there is any abnormality on the driving section of each motor or the roller. Correct if any.

← Xem tất cả mã lỗi Toshiba e-Studio 6530c

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie