Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E540 — Toshiba e-Studio 6540c

Code: E540

Description: ADU misfeeding (Paper not reaching the ADU feed sensor): Paper does not reach the duplexing unit path exit sensor after it has passed the duplexing unit path entrance sensor.
Causes: Duplexing unit path exit sensor ADU motor-1 ADU motor-2 PFC board ADU board Rollers
Remedy: Duplexing unit path exit sensor • Sensor check (Perform the input check: 03-[SCAN]ON/[3]/[G]) • Connector check • Harness check ADU motor-1 • Motor check (Perform the output check: 03-146) • Connector check • Harness check ADU motor-2 • Motor check (Perform the output check: 03-144) • Connector check • Harness check PFC board • Connector check (CN511, CN515) • Board check ADU board • Connector check (CN491, CN492) • Board check Drive unit, Rollers • Gear check • Roller check

← Xem tất cả mã lỗi Toshiba e-Studio 6540c