Code: E091
Description: Other time-out jam: The equipment does not operate normally because abnormality occurred on an interface between the SYS board and engine firmware.
Remedy: 1. Check if there is any paper in the equipment. Remove it if there is. 2. If the error still occurs, check the following: 3. Check if the error is cleared by turning the power OFF and then back ON. 4. Check if the connectors connecting the SYS board, SYSIF board, SLG board and PLG board are disconnected. 5. Check if the connectors of the HDD are disconnected. 6. Check if the page memory is connected to the connector on the SYS board properly. 7. Replace the page memory. 8. Check if the harnesses connecting the SYSIF board, SLG board and PLG board are opencircuited. 9. Replace the HDD, SYS board, SLG board and PLG board.