Description: Incorrect cam position alarm during 2nd transfer
Causes: Actuator in the TRU Sensors in the TRU
Remedy: 1 2nd transfer contact/release cam unit gear Check that it is not damaged. 2 Actuator in the TRU • Check that it is installed properly. • Check that it is not damaged. 3 Sensors in the TRU • Check that they are installed properly. • Check that the cam is not damaged. 4 If any abnormality on a part is detected and the part is replaced, the 2nd transfer pressure reduction is enabled by changing the value of the setting codes as follows: 08-4663: 0 to 10: Pressure reduction disabled1: Pressure reduction enabled 08-4664: 3 to 0Resetting incorrect cam position error count Notes: Change the value of the following codes to disable the pressure reduction: 08-4663: 1 to 0 0: Pressure reduction disabled 1: Pressure reduction enabled 08-4664: 0, 1 or 2 to 3 Resetting incorrect cam position error count