Code: E110
Description: ADU misfeeding (Paper not reaching the registration sensor): The paper which has passed through ADU does not reach the registration sensor during duplex printing.
Causes: Registration sensor ADU motor2 ADU board PFC board LGC board ADU roller
Remedy: Registration sensor • Sensor check (Perform the input check: 03-[ALL]OFF/[4]/[B], 03-[COPY]ON/[5]/[H]) • Connector check • Harness check ADU motor2 • Motor check (Perform the output check: 03-144) • Connector check (CN491, CN495) • Harness check LGC board • Connector check (CN309) • Board check Drive unit, Rollers • Gear check • Roller check PFC board • Connector check (CN500, CN515) • Harness check • Board check