Mã lỗi F090 — Toshiba e-Studio 6550c

Code: F090

Description: SRAM abnormality on the SYS board
Causes: SRAM (SYS board)
Remedy: 2. When “SRAM REQUIRES INITIALIZATION” is displayed on the LCD, check the destination and then press the [START] button. If the destination is not correct, key in the correct one and then press the [START] button. 3. After the confirmation message is displayed on the LCD, press the [INTERRUPT] button (to initialize the SRAM). 4. Perform the panel calibration (08-9050). 5. Enter the serial number (08-9601). Be sure that the serial number is the same as that on the identification label attached on the rear cover of the equipment. 6. Initialize the NIC information (08-9083). 7. Turn the power OFF and then start up with the Adjustment mode (05). 8. Perform “Data transfer of characteristic value of scanner” (05-3203). 9. Perform “Automatic gamma adjustment” <PRC> (05- 7869) (using [4] [FAX] test pattern). 10.Perform “Automatic gamma adjustment” <PRT (600dpi)> (05-8008) (using [70] [FAX] test pattern). 11.Perform “Automatic gamma adjustment” <PRT (1200dpi)> (05-8009) (using [230] [FAX] test pattern). 12.Turn the power OFF and then back ON. If the error is not recovered, replace the SRAM on the SYS board.