Code: CB30
Description: Tray lift motor abnormality
Remedy: [Procedure 1] Is the tray 1 home position sensor (PI8) working properly? → NO → Replace the tray 1 home position sensor. YES Is the tray 1 lifting mechanism working properly? → NO → Correct the defect of the mechanism. YES Is 24V supplied to the tray1 lifting motor (M5) from the finisher control board at the timing of tray driving? → NO → Replace the finisher control board. YES Is the harness between the finisher control board and tray 1 lifting motor normal? → NO → Replace the harness. YES Replace the tray 1 lifting motor. [Procedure 2] Is the tray 1 lifted/lowered? ↓ → YES → Is the wiring between the finisher controller PC board and tray 1 lifting motor normal? → NO → Correct the wiring. YES Replace the tray 1 lifting motor. NO Is the power supplied to the motor from the finisher control board at the timing of tray 1 lifting? → NO → Replace the finisher control board. YES Correct the defect of the mechanism. [Procedure 3] Is the tray 2 home position sensor (PI25) working properly? → NO → Replace the tray 2 home position sensor. YES Is the tray 2 lifting mechanism working properly? → NO → Correct the defect of the mechanism. YES Is 24V supplied to the tray 2 lifting motor (M10) from the finisher control board at the timing of tray driving? → NO → Replace the finisher control board. YES Is the harness between the finisher control board and tray 2 lifting motor normal? → NO → Replace the harness. YES Replace the tray 2 lifting motor. [Procedure 4] Is the tray 2 lifted/lowered? ↓ → YES → Is the harness between the finisher control board and tray 2 lifting motor normal? → NO → Correct the wiring. YES Replace the tray 2 lifting motor. NO Is the power supplied to the motor from the finisher control board at the timing of tray 2 lifting? → NO → Replace the finisher control board. YES Is there any abnormality at the tray 2 lifting mechanism? → YES → Correct the defect of the mechanism. NO Replace the tray 2 lifting motor. [Procedure 5] Is the tray lifting mechanism working properly? → NO → Correct the defect of the mechanism. YES Is the tray coming close detection switch working properly? → NO → Replace the switch. YES Replace the finisher controller PC board.