Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C449 — Toshiba e-Studio 6560C

Code: C449

Description: IH abnormality after abnormality judgment (high temperature abnormality)
Causes: Thermopiles Fuser unit IH coil IH board LGC board
Remedy: Power supply • Check if the power voltage is normal.(Is the voltage during the operation ±10% of the rated voltage?) Error detection history Check the error detection history of each temperature detecting element when the error occurred. If any of the elements detects an abnormal temperature, check next. • 08-4530: Fuser belt center thermopile temperature • 08-4532: Fuser belt edge thermistor temperature • 08-4533: Pressure roller center thermistor temperature • 08-4545: Pressure roller rear thermistor temperature Thermopiles • Check if the fuser belt center and side thermopiles (front, rear) are installed properly. • Check if the harnesses of the fuser belt center and side thermopiles (front, rear) are open circuited. Fuser unit • Unit check • Connector check • Harness check IH coil • Connector check • Harness check IH board • Connector check • Harness check LGC board • Connector check (CN305, CN306) • Harness check Status counter 1. [0], [8] Power ON. 2. Key in “2002”, then press [START]. 3. Change the current status counter value (08-2002) “3”, “5”, “6”, “9”, “19”, “21”, “22”, “23”, “24”, “25”, “27” or “29” to “0” for [C44X], taking the same procedure as that for [C41X]) 4. Turn the power OFF and then back ON. Make sure that the equipment enters the normal ready state. The status counter value is as follows in the following cases. • The error occurred during warming-up: “3”, “5” or “6” • The error occurred after the equipment has become ready: “7” • The temperature detected by the fuser belt center thermopile is 230?C or higher, the temperature detected by the side thermopile is 230?C or higher or the temperature detected by the edge thermopile is 230?C or higher: “9”, “19”, “21”, “22”, “23”, “25”, “27” or “29”. • The error occurred during printing: “24” or “25” • The error occurred during energy saving: “27” • A paper jam occurred: “29”

← Xem tất cả mã lỗi Toshiba e-Studio 6560C

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie