Code: CC10
Description: Microswitch abnormality: Any of the inlet door switch, delivery door switch and front cover closing detection switch is opened while all the covers are closed.
Remedy: [Procedure 1] Is the switch actuator for the inlet door working properly? → NO → Fix the mechanism. YES Is the inlet cover switch (MS1S) working normally? → NO → Replace the switch. YES Measure the voltage of J10-8 on the saddle stitcher controller PC board when the inlet door is open. Is it 5V? → NO → The inlet cover sensor (PI9S) is broken. Replace it. YES Measure the voltage between J1-1 (+) and J1-2 (-) on the saddle stitcher controller PC board. Is it 24 V? → NO → Replace the saddle stitcher controller PC board. YES Check the wiring between J19 on the finisher controller PC board and J1 on the saddle stitcher controller PC board. If there is no problem, replace the saddle stitcher controller PC board. [Procedure 2] Is the switch actuator for the front door working properly? → NO → Fix the mechanism. YES Is the front cover switch (MS2S) working normally? → NO → Replace the switch. YES Measure the voltage of J11-12 on the saddle switcher controller PC board when the front door is opened. Is it 5V? → NO → The front door opening/closing sensor is broken. Replace it. YES Replace the saddle stitcher controller PC board. [Procedure 3] Is the switch actuator for the delivery door working properly? → NO → Fix the mechanism. YES Is the delivery cover switch working normally? → NO → Replace the switch. YES Measure the voltage of J11-9 on the saddle stitcher controller PC board when the delivery door is opened. Is it 5V ? → NO → The delivery cover sensor (PI3S) is broken. Replace it. YES Replace the saddle stitcher controller PC board.