Mã lỗi CB70 — Toshiba e-Studio 657

Code: CB70

Description: Stack amount detection sensor abnormality
Remedy: [Procedure 1] Is the problem solved by turning OFF and ON the power of the equipment? → YES → END NO Is the wiring between the finisher controller PC board and the height sensor (PS1) correct? → YES → Correct the wiring. NO Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC? → NO → Replace the finisher controller PC board. YES Re-adjust the height sensor. Replace the height sensor if it still causes the problem. [Procedure 2] Is the connector J6 on the finisher controller PC board, J114 of the height sensor (PS1) or relay connector J212 and J213 (Only for MJ-1027/1028) disconnected? → YES → Connect the connector(s). NO Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC? → NO → Replace the finisher controller PC board. YES Is the wiring between the finisher controller PC board and height sensor correct? → YES → Correct the wiring. NO Replace the height sensor. [Procedure 3] Is the problem solved by readjusting the DIP switch? → YES → END NO Is the wiring between the finisher controller PC board and height sensor (PS1) correct? → YES → Correct the wiring. NO Is the voltage between J6-2(+) and J6-4(-) on the finisher controller PC board 5V DC? → NO → Replace the finisher controller PC board. YES Replace the height sensor.

← Xem tất cả mã lỗi Toshiba e-Studio 657

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie