Description: Cleaning brush drive motor abnormality: The cleaning brush drive motor does not run normally when the power is turned ON or the copying is started.
Remedy: (1) Check if the cleaning brush, recovery toner transport auger and recycle toner transport auger are not locked (no extraneous material or toner clod in both the toner transport sections at the cleaner unit and recycle toner unit). (2) Is the cleaning brush drive motor (M13) disconnected? (3) Check if the connector (CN337) on the LGC board and connector pins are not disconnected. (4) Replace the cleaning brush drive motor and recycle toner transport motor (M8). (5) Replace the LGC board.