Mã lỗi E540 — Toshiba e-Studio 7030c Pro

Code: E540

Description: ADU misfeeding (Paper not reaching the ADU feed sensor): Paper does not reach the duplexing unit path exit sensor after it has passed the duplexing unit path entrance sensor.
Remedy: 1. Is the duplexing unit path exit sensor working? (Perform the input check: 03-[SCAN]ON/[3]/[G].) * If it is working properly, proceed to 6. If not, check 2 to 5 below. 2. Check if the connector CN511 on the PFC board is disconnected from the duplexing unit path exit sensor or the harnesses are open circuited. Correct if so (including CN491 and CN492 on the ADU board). 3. Check if the duplexing unit path exit sensor is correctly installed or the actuator is properly moved. 4. Replace the duplexing unit path exit sensor. 5. Replace the PFC board. 6. Are the ADU motor-1 and the ADU motor-2 working? (Perform the output check: 03-146, 03- 144.) * If they are working properly, proceed to 11. If not, check 7 to 10 below. 7. Check if the connector CN511 on the PFC board is disconnected from the ADU motor-1 or the ADU motor-2, or the harnesses are open circuited. Correct if so (including CN491 and CN495 on the ADU board). 8. Replace the ADU motor-1 or the ADU motor-2. 9. Replace the ADU board. 10.Replace the PFC board. 11.Check if there is any abnormality on the driving section of the two motors or the roller. Correct if any.