Mã lỗi E570 — Toshiba e-Studio 7030c Pro

Code: E570

Description: Jam not reaching the bridge unit.
Remedy: 1. Is the reverse sensor working? (Perform the input check: 03-[SCAN]ON/[3]/[E].)) * If it is working properly, proceed to 6. If not, check 2 to 5 below. 2. Check if the connector CN514 on the PFC board is disconnected from the reverse sensor or the harnesses are open circuited. Correct if so (including CN538 and CN539 on the DRV board). 3. Check if the reverse sensor is correctly installed or its detecting element is not damaged or stained. 4. Replace the reverse sensor. 5. Replace the PFC board. 6. Are the bridge unit transport entrance motor and the fuser motor working? (Perform the output check: 03-130, 03-129.) * If they are working properly, proceed to 11. If not, check 7 to 10 below. 7. Check if the connector CN515 on the PFC board is disconnected from the bridge unit transport entrance motor or the fuser motor, or the harnesses are open circuited. Correct if so (including CN537 and CN539 on the DRV board). 8. Replace the bridge unit transport entrance motor or the fuser motor. 9. Replace the DRV board. 10.Replace the PFC board. 11.Check if there is any abnormality on the driving section of each motor or the roller. Correct if any.