Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi E721 — Toshiba e-Studio 7030c Pro

Code: E721

Description: Jam not reaching the original reading start sensor: The original does not reach the reading start sensor after it has passed the registration sensor (when scanning obverse side) or the reverse sensor (when scanning reverse side).
Remedy: 1. Clean the registration roller and the read roller if they are stained. 2. Is the reading start sensor working? (Perform the input check: 03-[FAX]ON/[7]/[G]) * If it is working properly, proceed to 8. If not, check 3 to 7 below. 3. Check if the connector CN75 on the RADF board is disconnected from the reading start sensor or the harnesses are open circuited. Correct if any. 4. Perform the automatic adjustment of the original reading start sensor (05-356). 5. Perform the manual adjustment of the original reading start sensor. 6. Replace the original reading sensor, and then perform the automatic adjustment of the original reading start sensor (05-356). 7. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356). 8. Replace the registration roller and the read roller if they are worn out.

← Xem tất cả mã lỗi Toshiba e-Studio 7030c Pro