Mã lỗi E860 — Toshiba e-Studio 7030c Pro

Code: E860

Description: Original jam access cover open: The Original jam access cover has opened during RADF operation.
Remedy: 1. Close the Original jam access cover if it is opened. Remove if there is any original before closing it. 2. Is the Original jam access cover opening/closing sensor working? (Perform the input check: 03- [FAX]ON/[7]/[C]) * If it is working properly, proceed to 6. If not, check 3 to 5 below. 3. Check if the connector CN8 on the RADF board is disconnected from the Original jam access cover opening/closing sensor or the harnesses are open circuited. Correct if any. 4. Replace the Original jam access cover opening/closing sensor. 5. Replace the RADF board, and then perform the automatic adjustment for the original reading start sensor (05-356).