Description: Option LCF tray-up motor abnormality: The Option LCF tray-up motor does not run normally or the Option LCF tray does not move normally. (Feeding of any other drawer than the Option LCF is possible.)
Remedy: Is the tray motor driving? (Perform the output check in the test mode: 03-271) ↓ → NO . 1) Check if the connector on the LCF tray motor is not disconnected. 2) Check if the connectors J851 on the LCF board are not disconnected. 3) Check if the connector of the tray-up sensor is not disconnected. 4) Check if the actuator reaches the sensor. 5) Replace the LCF board. 6) Replace the LGC board. YES Is the tray-up sensor working? (Perform the input check in the test mode: 03-[FAX] OFF/[5]/[E] ↓ → NO . 1) Check if the connector of the tray-up sensor is not disconnected. 2) Check if the connectors J851 on the LCF board are not disconnected. 3) Check if the actuator reaches the sensor. 4) Check if the connector pins are not disconnected and the harness is not open circuited. 5) Replace the LCF board. 6) Replace the LGC board. YES 1) Check if the tray lifting mechanism has no abnormality. 2) Replace the LCF board. 3) Replace the LGC board.