Description: Recycle toner transport motor abnormality: The recycle toner transport motor does not run normally when the power is turned ON or the copying is started.
Remedy: (1) Check if the recycle toner transport auger is not locked (no extraneous material or toner clod in both the transport sections at the toner recycle unit). (2) Is the Recycle toner transport motor (M8) disconnected? (3) Check if the connector (CN337) on the LGC board and connector pins are not disconnected. (4) Replace the recycle toner transport motor. (5) Replace the LGC board.