Code: CB90
Description: Paper pushing plate motor abnormality: The paper pushing plate motor does not run normally or the paper pushing plate does not move normally.
Remedy: [Procedure 1] Is the paper pushing plate home position sensor (PI14S) working normally? → NO → Replace the sensor. YES Is the paper pushing plate motor (M8S) operating at the fixed timing? → YES → Replace the saddle stitcher controller PC board. NO Is the paper pushing plate drive mechanism normal? → NO → Fix the mechanism. YES Is the problem solved by replacing the paper pushing plate motor (M8S)? → NO → Replace the saddle stitcher controller PC board. YES END [Procedure 2] Is the paper pushing plate top position sensor (PI15S) working normally? → NO → Replace the sensor. YES Is the paper pushing plate motor (M8S) operating at the fixed timing? → YES → Replace the saddle stitcher controller PC board. NO Is there any problem with the paper pushing plate drive mechanism? → YES → Fix the mechanism. NO Is the problem solved by replacing the paper pushing plate motor (M8S)? → NO → Replace the saddle stitcher controller PC board. YES END [Procedure 3] Is the paper pushing plate motor clock sensor (PI1S) working normally? → NO → Replace the sensor. YES Is the paper pushing plate motor (M8S) operating at the fixed timing? → YES → Replace the saddle stitcher controller PC board. NO Is there any problem with the pushing plate drive mechanism? → YES → Fix the mechanism. NO Is the problem solved by replacing the paper pushing plate motor (M8S)? → NO → Replace the saddle stitcher controller PC board. YES END