Mã lỗi E25 — Toshiba e-Studio 810

Code: E25

Description: Paper fed from the external LCF (not reaching the registration sensor)
Remedy: Is there any paper before the registration sensor when the bypass unit cover is opened? Remove the paper. Is the registration sensor working? (Perform the input check in the test mode: 03-[ENERGY SAVER]ON/[4]/[E]) 1. Check if the registration connector is not disconnected. 2. Check if the connector J341 on the LGC board is not disconnected. 3. Check if the connector pins are not disconnected and the harness is not open-circuited. 4. Check if the conductor pattern on the LGC board is not short- or opencircuited. 5. Replace the registration sensor. 6. Replace the LGC board. Is the external LCF transport motor driving? (Perform the output check in the test mode: 03-122/172) 1. Check if the connector of the transport motor is not disconnected. 2. Check if the connectors J801~804 on the LCF board are not disconnected. 3. Check if there is any abnormality at the transort drive unit. Is the external LCF feed clutch working? (Perform the output check in the test mode: 03-272) 1. Check if the external LCF clutch connector is not disconnected. 2. Check if the connectors J801~804 on the LCF board are not disconnected. 3. Check if the connector J346 on the LGC board is not disconnected. 4. Check if the connector pins are not disconnected and the harness is not open-circuited. 5. Check if the conductor pattern on the LCF and LGC boards is not short- or open-circuited. 6. Replace the external LCF feed clutch. 7. Replace the LCF board. 8. Replace the LGC board. Is the external LCF transport clutch working? (Perform the output check in the test mode: 03-273) 1. Check if the connector of the external LCF feed clutch is not disconnected. 2. Check if the connectors J801~804 on the LCF board are not disconnected. 3. Check if the connector J346 on the LGC board is not disconnected. 4. Check if the connector pins are not disconnected and the harness is not open-circuited. 5. Check if the conductor pattern on the LCF and LGC boards is not short- or open-circuited. 6. Replace the external LCF feed clutch. 7. Replace the LCF board. 8. Replace the LGC board. 1. Check if there is any abnormality at the transport drive unit. 2. Check the condition of the external LCF feed roller and separation roller and clean them, or if they are deteriorated, replace them.

← Xem tất cả mã lỗi Toshiba e-Studio 810

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie