Mã lỗi C850 — Toshiba e-Studio 850

Code: C850

Description: Tray lift motor abnormality
Remedy: Is the lifting tray lifted when originals are set on the feeding tray? ↓ → NO . Is the loading of the lifting tray normal? l → NO . Adjust the mechanical loading. Remove, if any, extraneous materials. YES Is the power voltage for CN5-5 and CN6 on the ADF board 24V? → NO . Replace the ADF board. YES Replace the lifting tray motor. YES Is the lifting tray upper limit detection sensor working properly when the lifting tray is lifted? → NO . Replace the lifting tray upper limit detection sensor. YES Is the lifting tray lowered when originals are removed from the original tray? ↓ → NO . ↓ → NO . Is the loading of the lifting tray abnormal, adjust the mechanical loading. Remove, if any, extraneous materials. YES YES 1) Replace the lifting tray lower limit detection sensor. 2) Replace the ADF board.