Mã lỗi CA10 — Toshiba e-Studio 856

Code: CA10

Description: Polygonal motor abnormality: The polygonal motor does not run normally.
Remedy: Is the polygonal motor rotating? ↓ → NO → (e-STUDIO555/655) 1. Check if the connector CN209 on the PLG board is disconnected. 2. Check if the harness is open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN209 on the PLG board. Pin 1: 27±1V, Pin 2: GND, Pin 5: Less than or equal to 1V (Lo), Pin 4: Less than or equal to 0.7 V (Lo), Pin 3: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Replace the laser optical unit. 6. Replace the PLG board. (e-STUDIO755/855) 1. Check if the connector CN206 on the PLG board is disconnected. 2. Check if the harness is open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN206 on the PLG board. Pin 5: 24±1V, Pin 4: GND, Pin 3: Less than or equal to 1V (Lo), Pin 2: Less than or equal to 0.7 V (Lo), Pin 1: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Replace the laser optical unit. 6. Replace the PLG board. YES Is the deformed image output? ↓ → NO → (e-STUDIO555/655) 1. Check if the connector CN209 on the PLG board is about to be disconnected. 2. Check if the harness is about to be open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN209 on the PLG board. Pin 1: 27±1V, Pin 2: GND, Pin 5: Less than or equal to 1V (Lo), Pin 4: Less than or equal to 0.7 V (Lo), Pin 3: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Check if the laser unit cooling fan is not stopped. 6. Check if the intake area of the laser unit cooling fan is not blocked. 7. Replace the laser optical unit. 8. Replace the PLG board. (e-STUDIO755/855) 1. Check if the connector CN206 on the PLG board is about to be disconnected. 2. Check if the harness is about to be open circuited and the connector pin is disconnected. 3. Check if the following signals are transmitted on the pins of the connector CN206 on the PLG board. Pin 5: 24±1V, Pin 4: GND, Pin 3: Less than or equal to 1V (Lo), Pin 2: Less than or equal to 0.7 V (Lo), Pin 1: Do not touch. 4. Check if the conductor pattern on the PLG board is short circuited or open circuited. 5. Check if the laser unit cooling fan is not stopped. 6. Check if the intake area of the laser unit cooling fan is not blocked. 7. Replace the laser optical unit. 8. Replace the PLG board. YES 1. Check if the conductor pattern on the PLG board is short circuited or open circuited. 2. Check if the grounding wire of the high-voltage unit (e.g. developer unit, transfer unit) is grounded securely. 3. Check if the bias contact point of the high-voltage unit is contacted securely. (Check if the point is not stained either.) 4. Check if the metal plates of the transport system are grounded securely. 5. Check if the equipment is grounded securely? 6. Check if the laser unit cooling fan is not stopped. 7. Check if the intake area of the laser unit cooling fan is not blocked. 8. Replace the laser optical unit.

← Xem tất cả mã lỗi Toshiba e-Studio 856

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie