Description: Transport jam during duplex printing (paper not reaching horizontal transport sensor-3): Paper which has passed the horizontal transport sensor-2 does not reach the horizontal transport sensor-3 during duplex printing.
Remedy: (Perform the input check in the test mode: 03-[FAX]OFF/[9]/[H]) ↓ → NO → 1. Check if the connector of the Horizontal transport sensor-3 is not disconnected. 2. Check if the connector CN334 on the LGC board is not disconnected. 3. Check if the connector pins are not disconnected and the harness is not open circuited. 4. Check is the conductor pattern on the LGC board is not short- or open-circuited. 5. Replace the Horizontal transport sensor-3. 6. Replace the LGC board. YES Check the condition of the roller at the horizontal transport section and clean or replace it.