Mã lỗi CB90 — Toshiba e-Studio 856SE

Code: CB90

Description: Paper pushing plate motor abnormality: The paper pushing plate motor does not run normally or the paper pushing plate does not move normally.
Remedy: [Procedure 1] Is the paper pushing plate home position sensor (PI14S) working normally? → NO → Replace the sensor. YES Is the paper pushing plate motor (M8S) operating at the fixed timing? → YES → Replace the saddle stitcher controller PC board. NO Is the paper pushing plate drive mechanism normal? → NO → Fix the mechanism. YES Is the problem solved by replacing the paper pushing plate motor (M8S)? → NO → Replace the saddle stitcher controller PC board. YES END [Procedure 2] Is the paper pushing plate top position sensor (PI15S) working normally? → NO → Replace the sensor. YES Is the paper pushing plate motor (M8S) operating at the fixed timing? → YES → Replace the saddle stitcher controller PC board. NO Is there any problem with the paper pushing plate drive mechanism? → YES → Fix the mechanism. NO Is the problem solved by replacing the paper pushing plate motor (M8S)? → NO → Replace the saddle stitcher controller PC board. YES END [Procedure 3] Is the paper pushing plate motor clock sensor (PI1S) working normally? → NO → Replace the sensor. YES Is the paper pushing plate motor (M8S) operating at the fixed timing? → YES → Replace the saddle stitcher controller PC board. NO Is there any problem with the pushing plate drive mechanism? → YES → Fix the mechanism. NO Is the problem solved by replacing the paper pushing plate motor (M8S)? → NO → Replace the saddle stitcher controller PC board. YES END

← Xem tất cả mã lỗi Toshiba e-Studio 856SE

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie