Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C0A — Toshiba FC211

Code: C0A

Description: Developer motor rotation abnormal
Remedy: Is the developer motor rotating properly? N: 1. Check if the connector J41 or J43 of the developer motor is disconnected. 2. Check if the connector J109 on the LGC board is disconnected. 3. Check if the connector J703 of the switching power supply is disconnected. 4. Check if the harness between the LGC board and the developer motor is open-circuited. 5. Check if the harness between the switching power supply and the developer motor is open-circuited. 6. Check if any harness is open-circuited or any connector pin is disconnected. 7. Rotate the motor manually, counterclockwise as seen from its back, and if the motor load is abnormal, remove any foreign matter from the drive unit. (Do not try to rotate the motor clockwise as seen from its back.) 8. Replace the developer motor. 9. Replace the LGC board. Y: Are the pins B12 and B16 of the connector J109 on the LGC board always at the level "L"? N: 1. Check if the connector J41 of the developer motor is disconnected. 2. Check if the connector J109 on the LGC board is disconnected. 3. Check if any conductor pattern on the LGC board is open- or short-circuited. 4. Check if any harness is open-circuited or any connector pin is disconnected. 5. Replace the LGC board. 6. Replace the developer motor. Y: 1. Check if any conductor pattern on the LGC board is open- or short-circuited. 2. Replace the LGC board. 3. Replace the developer motor.

← Xem tất cả mã lỗi Toshiba FC211

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie