Code: E000-0000
Description: Error in start-up of fixing assembly
Causes: When 1 sec passed after energization of the heater, the detected temperature of the main thermistor is not 5 deg C or more (0 deg C at power on). Cause Disconnection of main thermistor, disconnection of fixing heater, error in DC controller PCB.
Remedy: - Check of the connector of the low-voltage power supply PCB - Replacement of fixing sleeve unit - Replacement of DC controller PCB