Code: L6-10
Description: Polygon motor lock
The lock signal (the specified rotation speed signal) is not supplied within the specified time (about 6 sec)after starting the polygon motor rotation.
The lock signal (the specified rotation speed signal) is not supplied within the specified time (about 6 sec)after starting the polygon motor rotation.
Causes: LSU connector disconnection or harness disconnection in the LSU.
Remedy: Check the operation of the polygon motor with SIM 25-10. Check the harness and the connector connection. LSU replacement