Code: U2-11
Description: Counter check sum error
Counter check sum value stored in the EEPROM is abnormal.
Counter check sum value stored in the EEPROM is abnormal.
Causes: EEPROM failure Control circuit hung up by noises MCU PWB EEPROM access circuit defect
Remedy: Check that the EEPROM is properly set. To prevent against loss of counter/adjustment values, record the values with simulation. U2 trouble cancel with SIM 16 MCU PWB replacement