Code: H3-00
Description: Fusing high temperature trouble DETAIL 1) Fusing temperature sensor (thermistor) output level abnormality 2) Fusing temperature sensor (thermistor) output level recognition error
Remedy: Fusing temperature sensor (thermistor) signal recognition error 1) Fusing temperature sensor (thermistor) trouble 2) MCU PWB temperature sensor (thermistor) input circuit trouble 3) Fusing temperature sensor (thermistor) dirt REMEDY (Check) 1) Fusing temperature sensor (thermistor) 2) MCU PWB fusing temperature sensor (thermistor) input circuit (Remedy) 1) Fusing temperature sensor (thermistor) replacement 2) MCU PWB replacement 3) Fusing temperature sensor (thermistor) cleaning 4) Reset the trouble with SIM 14. (After work) 1) When the MCU PWB is replaced, perform simulations to input various set values and adjustment values. TROUBLE POSITION CAUSE Heater lamp control signal trouble 1) MCU PWB heater lamp control circuit trouble REMEDY (Check) 1) MCU PWB (Remedy) 1) MCU PWB replacement 2) Reset the trouble with SIM 14. (After work) 1) When the MCU PWB is replaced, perform simulations to input various set values and adjustment values. TROUBLE POSITION CAUSE Heater lamp drive trouble 1) Power PWB heater lamp drive circuit trouble REMEDY (Check) 1) Power PWB (Remedy) 1) Power PWB replacement 2) Reset the trouble with SIM 14. (After work).