Mã lỗi E1-84 — Sharp AR317FP
Code:
E1-84
Description: IMC PWB communication trouble (Framing)
Communication trouble between MCU and IMC PWB (Framing error)
Causes: IMC PWB connector disconnection Motherboard connector pin breakage IMC PWB ROM defect, data failure
Remedy: Check the connectors of the IMC PWB and MCU PWB. Check the grounding of the copier. Check the ROM of the IMC PWB.
← Xem tất cả mã lỗi Sharp AR317FP