Code: H4-01
Description: Sub heater lamp abnormally low temperature detection
The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power ON SW. (When the temperature of sub heater thermistor falls below 140°C in the standby mode or printing.) Whether temperature of sub heater lamp thermistor falls below 50°C in the pre-heat mode.
The setup temperature (about 90°C) is not reached within the specified time (about 17sec) from turning on the power ON SW. (When the temperature of sub heater thermistor falls below 140°C in the standby mode or printing.) Whether temperature of sub heater lamp thermistor falls below 50°C in the pre-heat mode.
Causes: Sub heater lamp thermistor defect Sub heater lamp failure Sub thermostat failure Control PWB failure
Remedy: Check the sub heater lamp blinking with SIM 5-2-2. When the lamp blinks normally: Check the thermistor and the harness. Check the MCU PWB thermistor input circuit. If lamp lights and stays lit: Check the power circuit and the lamp control circuit on MCU PWB. Clear the display of self-diagnostics with SIM 14.